Powering Your Business
iPSU-M60-48-4C
iPSU-M60-48-4C
is a 48VDC constant voltage, 4 channel, software controlled DCpower supply unit, a cost
effective solution for power needs in industrial automation and automated
test systems.
Each output channel can be controlled/monitored by either
SCPI or the software provided. Turn-on/off times, current limits and the action
in over current situation can be set and monitored remotely. Long term data
acquisition is also possible for all individual channels through the software.
Touch screen TFT display on the front panel provides
instant access to the settings. The display also comprises detailed information
about the status of each output channel, current/voltage measurements, uptime,
session Imax/Imin and current/time graph for each channel, etc.
Features
* Specifications and features mentioned here may be mutually exclusive and may change according to the configuration. Please check before ordering.
4.3" Touch Screen Display
Users can perform all operations such as management, configuration, monitoring and similar, using the multi-function touch screen in the front panel.
Here are some of the screens:
Specifications
|
OUTPUT RATING |
|
|
|
1.Rated output voltage |
V |
48 |
|
2.Total rated output current |
A |
60 |
|
3.Number of output channels |
--- |
4 |
|
4.Rated output current per channel |
A |
18A/Ch1&Ch2, 12A/Ch3&Ch4 |
|
5.Rated output power(*1) |
W |
3200 |
|
|
|
|
|
INPUT CHARACTERISTICS |
V |
|
|
1.Input voltage/freq. (*2) |
--- |
85~265VAC, continuous, 47~63Hz,Single Phase |
|
2. Maximum Input current at 100% load (100/200 VAC) |
A |
27A/14A |
|
3.Power Factor (Typ) |
--- |
0.98 @ 100VAC 0.94 @ 200VAC, rated output power. |
|
4.Efficiency at 100 Vac/200VAC, |
% |
81/83 |
|
5.Inrush current |
A |
80A |
|
|
|
|
|
CONSTANT VOLTAGE |
|
|
|
1.Max . Line regulation |
--- |
0.02% of rated output voltage |
|
2.Max . Load regulation |
--- |
0.02% of rated output voltage +2mV |
|
3.Ripple and noise (p-p, 20MHz)(*4)(*5) |
mV |
40mV max |
|
4.Ripple r.m.s. 5Hz~1MHz (*3)(*4) |
mV |
15mV |
|
5.Temperature coefficient |
%/°C |
0.02%/°C |
|
6.Temperature stability |
--- |
0.02% of rated Vout |
|
7.Remote sense compensation/wire |
V |
0.3 |
|
8.Transient response time |
mS |
Time for output voltage to recover within 0.5% of its rated
output for a load change 10~90% of rated output current. |
|
9.Start up delay |
Sec |
Less than 4 Sec |
|
10.Hold-up time |
mS |
20ms typical, rated output power |
|
|
|
|
|
PROTECTIVE FUNCTIONS |
||
|
1.Over Current Protection |
--- |
Programmable current limit. Over 10A switch channel OFF and ON to reset protection |
|
2.Over-voltage protection (OVP) |
--- |
Output shut-down. Reset by AC input recycle |
|
|
|
|
|
READBACK |
||
|
1.Voltage readback accuracy |
% |
0.05% at 48V |
|
2.Current readback accuracy |
% |
0.05% at 10A (channel max load) |
|
FRONT PANEL |
|
|
|
1.Front Panel Buttons Indications |
--- |
Output channel ON/OF push buttons and status leds |
|
2.Touch Screen Display |
--- |
Output channel ON/OFF |
|
|
--- |
Output voltage by channel |
|
|
--- |
Output current by channel |
|
|
--- |
Current Limit and limit behavior adjustment |
|
|
--- |
Sequential On/Off timer adjustment |
|
|
--- |
Zoom into preferred channel |
|
|
--- |
Live current graph with 1/10, 1, 10 seconds resolution |
|
|
--- |
IP network parameter adjustment |
|
ENVIRONMENTAL CONDITIONS |
|
|
|
1.Operating temperature |
--- |
-10~60°C |
|
2.Storage temperature |
--- |
-30~85°C |
|
3.Operating humidity |
% |
20~90% RH (no condensation). |
|
4.Storage humidity |
% |
10~95% RH (no condensation). |
|
5.Altitude |
--- |
Operating: 2000m |
|
|
||
|
MECHANICAL |
|
|
|
1.Cooling |
--- |
Forced air cooling by internal fans. Air flow direction: |
|
2.Weight |
kg |
22kg |
|
3.Dimensions (WxHxD) |
mm |
428 x 133 x 556 (Without handles, connectors and busbars) |
|
SAFETY/EMC |
|
|
|
1. Applicable standards: Safety |
--- |
IEC 62368-1 |
|
1.2. Withstand voltage |
VAC |
Output to ground 500 for 1 minute, Input to ground 2,000, |
|
1.3. Insulation resistance |
MOhm |
>100 at 25°C, 70%RH & 500Vdc |
|
2. Conducted emmision |
--- |
EN55032-B |
|
3.Radiated emission |
--- |
EN55032-B |
|
4. EMC compliance |
--- |
|
|
4.1. ESD |
--- |
EN61000-4-2, Air ± 8kV and contact ± 4kV |
|
4.2. Radiated Susceptibility |
--- |
EN61000-4-3, 80M -1GHz: 10V/m , 1.4 - 2.0GHz: 3V/m, 2.0 - 2.7GHz: 1V/m |
|
4.3. Electrical Fast Transient Burst |
--- |
EN61000-4-4, ± 2kV |
|
4.4. Surge |
--- |
EN61000-4-5, Normal ± 2kV, Common ± 4kV |
|
4.5. Conducted Susceptibility |
--- |
EN61000-4-6, 10Vrms |
|
4.6. Magnetic Fields |
--- |
EN61000-4-8, 30A/m |
*1. Total output power is limited to 2880 Watts by software. 3200 Watts output is achievable in air conditioned environments.
*2. For cases where conformance to various safety standards (UL, IEC etc.) is required, to be described as 100-240Vac (50/60Hz).
*3. At 100/200V input voltage and maximum output power.
*4. The ripple is measured at 100% output current.
*5. At 100/200V input voltage and maximum output power.